Skip to main content
CUI

Vulnerability V-254394

Back

V-254394

CAT I

Windows Server 2022 Active Directory Domain Controllers Organizational Unit (OU) object must have the proper access control permissions.

Ships Affected
1
Total Findings
1
Open
0
Closed
0

Check Text

This applies to domain controllers. It is NA for other systems. Review the permissions on the Domain Controllers OU. Open "Active Directory Users and Computers" (available from various menus or run "dsa.msc"). Select "Advanced Features" in the "View" menu if not previously selected. Select the "Domain Controllers" OU (folder in folder icon). Right-click and select "Properties". Select the "Security" tab. If the permissions on the Domain Controllers OU do not restrict changes to System, Domain Admins, Enterprise Admins and Administrators, this is a finding. The default permissions listed below satisfy this requirement. Domains supporting Microsoft Exchange will have additional Exchange related permissions on the Domain Controllers OU. These may include some change related permissions and are not a finding. The permissions shown are at the summary level. More detailed permissions can be viewed by selecting the "Advanced" button, the desired Permission entry, and the "View" or "Edit" button. Except where noted otherwise, the special permissions may include a wide range of permissions and properties and are acceptable for this requirement. CREATOR OWNER - Special permissions SELF - Special permissions Authenticated Users - Read, Special permissions The special permissions for Authenticated Users are Read types. If detailed permissions include any Create, Delete, Modify, or Write Permissions or Properties, this is a finding. SYSTEM - Full Control Domain Admins - Read, Write, Create all child objects, Generate resultant set of policy (logging), Generate resultant set of policy (planning), Special permissions Enterprise Admins - Full Control Key Admins - Special permissions Enterprise Key Admins - Special permissions Administrators - Read, Write, Create all child objects, Generate resultant set of policy (logging), Generate resultant set of policy (planning), Special permissions Pre-Windows 2000 Compatible Access - Special permissions The Special permissions for Pre-Windows 2000 Compatible Access are Read types. If detailed permissions include any Create, Delete, Modify, or Write Permissions or Properties, this is a finding. ENTERPRISE DOMAIN CONTROLLERS - Read, Special permissions

Fix Text

Limit the permissions on the Domain Controllers OU to restrict changes to System, Domain Admins, Enterprise Admins and Administrators. The default permissions listed below satisfy this requirement. Domains supporting Microsoft Exchange will have additional Exchange related permissions on the Domain Controllers OU. These may include some change related permissions. CREATOR OWNER - Special permissions SELF - Special permissions Authenticated Users - Read, Special permissions The special permissions for Authenticated Users are Read types. SYSTEM - Full Control Domain Admins - Read, Write, Create all child objects, Generate resultant set of policy (logging), Generate resultant set of policy (planning), Special permissions Enterprise Admins - Full Control Key Admins - Special permissions Enterprise Key Admins - Special permissions Administrators - Read, Write, Create all child objects, Generate resultant set of policy (logging), Generate resultant set of policy (planning), Special permissions Pre-Windows 2000 Compatible Access - Special permissions The special permissions for Pre-Windows 2000 Compatible Access are Read types. ENTERPRISE DOMAIN CONTROLLERS - Read, Special permissions

STIG Reference

STIG
Microsoft Windows Server 2022 Security Technical Implementation Guide
Version
2
Release
8
Rule ID
SV-254394r958726_rule

All Occurrences

This vulnerability appears on 1 ship(s)

Ship Hull # Source File Status Assigned To Scan Date Actions
LAB BASELINES BASELINE SCHR-P3-DP-001_WinServer2022_V2R7_20260305-133436.cklb
Unassigned 2026-03-05T13:34:36 View in Context