Skip to main content
CUI

Vulnerability V-228384

Back

V-228384

CAT III

The Exchange Receive Connector Maximum Hop Count must be 60.

Ships Affected
1
Total Findings
1
Open
0
Closed
1

Check Text

Review the Email Domain Security Plan (EDSP) or document that contains this information. Determine the Max Hop Count value for Receive connectors. Open the Exchange Management Shell and enter the following command: Get-ReceiveConnector | Select Name, MaxHopCount For each Receive connector, if the value of "MaxHopCount" is not set to "60", this is a finding. or If the value of "MaxHopCount" is set to a value other than "60" and has signoff and risk acceptance in the EDSP, this is not a finding.

Fix Text

Update the EDSP to specify the "MaxHopCount" value or verify that this information is documented by the organization. Open the Exchange Management Shell and enter the following command: Set-ReceiveConnector -MaxHopCount 60 or Enter the value as identified by the EDSP that has obtained a signoff with risk acceptance. Repeat the procedure for each Receive connector.

STIG Reference

STIG
Microsoft Exchange 2016 Mailbox Server Security Technical Implementation Guide
Version
2
Release
6
Rule ID
SV-228384r879651_rule

All Occurrences

This vulnerability appears on 1 ship(s)

Ship Hull # Source File Status Assigned To Scan Date Actions
USNS MONTFORD POINT T-ESD-1 _Reviewed/MONT-MB-002/Checklist/MONT-MB-002_MSExchange2016MB_V2R6_20251023-152357.ckl
Unassigned 2026-01-14T12:57:33.455034 View in Context