Skip to main content
CUI

Vulnerability V-224862

Back

V-224862

CAT III

The time service must synchronize with an appropriate DoD time source.

Ships Affected
1
Total Findings
8
Open
1
Closed
7

Check Text

Review the Windows time service configuration. Open an elevated "Command Prompt" (run as administrator). Enter "W32tm /query /configuration". Domain-joined systems (excluding the domain controller with the PDC emulator role): If the value for "Type" under "NTP Client" is not "NT5DS", this is a finding. Other systems: If systems are configured with a "Type" of "NTP", including standalone or nondomain-joined systems and the domain controller with the PDC Emulator role, and do not have a DoD time server defined for "NTPServer", this is a finding. To determine the domain controller with the PDC Emulator role: Open "PowerShell". Enter "Get-ADDomain | FT PDCEmulator".

Fix Text

Configure the system to synchronize time with an appropriate DoD time source. Domain-joined systems use NT5DS to synchronize time from other systems in the domain by default. If the system needs to be configured to an NTP server, configure the system to point to an authorized time server by setting the policy value for Computer Configuration >> Administrative Templates >> System >> Windows Time Service >> Time Providers >> "Configure Windows NTP Client" to "Enabled", and configure the "NtpServer" field to point to an appropriate DoD time server. The US Naval Observatory operates stratum 1 time servers, which are identified at: https://www.cnmoc.usff.navy.mil/Our-Commands/United-States-Naval-Observatory/Precise-Time-Department/Network-Time-Protocol-NTP/ Time synchronization will occur through a hierarchy of time servers down to the local level. Clients and lower-level servers will synchronize with an authorized time server in the hierarchy.

STIG Reference

STIG
Microsoft Windows Server 2016 Security Technical Implementation Guide
Version
2
Release
10
Rule ID
SV-224862r1038944_rule

All Occurrences

This vulnerability appears on 1 ship(s)

Ship Hull # Source File Status Assigned To Scan Date Actions
USNS MONTFORD POINT T-ESD-1 _Reviewed/MONT-AP-002/Checklist/MONT-AP-002_WinServer2016_V2R10_20251023-144214.ckl
Unassigned 2026-01-14T12:57:42.721079 View in Context
USNS MONTFORD POINT T-ESD-1 _Reviewed/MONT-BE-002/Checklist/MONT-BE-002_WinServer2016_V2R10_20251023-143943.ckl
Unassigned 2026-01-14T12:57:41.363810 View in Context
USNS MONTFORD POINT T-ESD-1 _Reviewed/MONT-DB-002/Checklist/MONT-DB-002_WinServer2016_V2R10_20251023-144132.ckl
Unassigned 2026-01-14T12:57:39.082634 View in Context
USNS MONTFORD POINT T-ESD-1 _Reviewed/MONT-DC-003/Checklist/MONT-DC-003_WinServer2016_V2R10_20251023-172220.ckl
Unassigned 2026-01-14T12:57:37.248886 View in Context
USNS MONTFORD POINT T-ESD-1 _Reviewed/MONT-DP-001/Checklist/MONT-DP-001_WinServer2016_V2R10_20251023-144106.ckl
Unassigned 2026-01-14T12:57:35.637816 View in Context
USNS MONTFORD POINT T-ESD-1 _Reviewed/MONT-MB-002/Checklist/MONT-MB-002_WinServer2016_V2R10_20251023-152736.ckl
Unassigned 2026-01-14T12:57:33.842838 View in Context
USNS MONTFORD POINT T-ESD-1 _Reviewed/MONT-VSF-003/Checklist/MONT-VSF-003_WinServer2016_V2R10_20251023-143935.ckl
Unassigned 2026-01-14T12:57:31.534241 View in Context
USNS MONTFORD POINT T-ESD-1 _Reviewed/MONT-VSF-004/Checklist/MONT-VSF-004_WinServer2016_V2R10_20251023-143909.ckl
Unassigned 2026-01-14T12:57:30.046447 View in Context
CUI