V-223288
CAT IIActiveX Controls must be initialized in Safe Mode.
- Ships Affected
- 1
- Total Findings
- 4
- Open
- 0
- Closed
- 4
Check Text
Verify the policy value for User Configuration >> Administrative Templates >> Microsoft Office 2016 >> Security Settings "ActiveX Control Initialization" is set to "Enabled (If SFI, load the control in safe mode and use persisted values (if any). If not SFI, prompt the user and advise them that it is marked unsafe. If the user chooses No at the prompt, do not load the control. Otherwise, load it with persisted values.)
Use the Windows Registry Editor to navigate to the following key:
HKCU\Software\Policies\Microsoft\Office\Common\Security
If the value UFIControls is set to REG_DWORD=6, this is not a finding.
Fix Text
Set the policy value for User Configuration >> Administrative Templates >> Microsoft Office 2016 >> Security Settings "ActiveX Control Initialization" to "Enabled + 6".
STIG Reference
- STIG
- Microsoft Office 365 ProPlus Security Technical Implementation Guide
- Version
- 3
- Release
- 5
- Rule ID
- SV-223288r961779_rule
All Occurrences
This vulnerability appears on 1 ship(s)
| Ship | Hull # | Source File | Status | Assigned To | Scan Date | Actions |
|---|---|---|---|---|---|---|
| USNS MONTFORD POINT | T-ESD-1 | MONT-SW-89134_MSOffice365_V3R4_20251217-201101.ckl | Unassigned | 2026-03-04T15:25:42.171357 | View in Context | |
| USNS MONTFORD POINT | T-ESD-1 | MONT-SW-89108_MSOffice365_V3R4_20251217-202911.ckl | Unassigned | 2026-03-04T15:25:16.145630 | View in Context | |
| USNS MONTFORD POINT | T-ESD-1 | _Reviewed/MONT-WS-92010/Checklist/MONT-WS-92010_MSOffice365_V3R3_20251023-141031.ckl | Unassigned | 2026-01-14T12:57:28.231385 | View in Context | |
| USNS MONTFORD POINT | T-ESD-1 | _Reviewed/MONT-WS-92040/Checklist/MONT-WS-92040_MSOffice365_V3R3_20251023-142330.ckl | Unassigned | 2026-01-14T12:57:25.987513 | View in Context |