CAT II

The Force shutdown from a remote system user right must only be assigned to the Administrators group.

Ships Affected
1
Total Findings
4
Open
0
Closed
4

Check Text

Verify the effective setting in Local Group Policy Editor. Run "gpedit.msc". Navigate to Local Computer Policy >> Computer Configuration >> Windows Settings >> Security Settings >> Local Policies >> User Rights Assignment. If any groups or accounts other than the following are granted the "Force shutdown from a remote system" user right, this is a finding: Administrators

Fix Text

Configure the policy value for Computer Configuration >> Windows Settings >> Security Settings >> Local Policies >> User Rights Assignment >> "Force shutdown from a remote system" to only include the following groups or accounts: Administrators

STIG Reference

STIG
Microsoft Windows 10 Security Technical Implementation Guide
Version
3
Release
6
Rule ID
SV-220974r958726_rule

All Occurrences

This vulnerability appears on 1 ship(s)

Ship Hull # Source File Status Assigned To Scan Date Actions
USNS MONTFORD POINT T-ESD-1 MONT-SW-89134_Win10_V3R5_20251217-201218.ckl
Unassigned 2026-03-04T15:25:42.339596 View in Context
USNS MONTFORD POINT T-ESD-1 MONT-SW-89108_Win10_V3R5_20251217-203019.ckl
Unassigned 2026-03-04T15:25:16.342077 View in Context
USNS MONTFORD POINT T-ESD-1 _Reviewed/MONT-WS-92010/Checklist/MONT-WS-92010_Win10_V3R4_20251023-141133.ckl
Unassigned 2026-01-14T12:57:28.689048 View in Context
USNS MONTFORD POINT T-ESD-1 _Reviewed/MONT-WS-92040/Checklist/MONT-WS-92040_Win10_V3R4_20251023-142421.ckl
Unassigned 2026-01-14T12:57:26.690022 View in Context