V-206623
CAT IIThe DBMS must generate audit records when unsuccessful attempts to modify categories of information (e.g., classification levels/security levels) occur.
- Ships Affected
- 1
- Total Findings
- 1
- Open
- 0
- Closed
- 0
Check Text
Review DBMS documentation to verify that audit records can be produced when the system denies or fails to complete attempts to modify categories of information.
If the DBMS is not capable of this, this is a finding.
Review the DBMS/database security and audit configurations to verify that audit records are produced when the system denies attempts to modify categories of information.
If they are not produced, this is a finding.
Review the DBMS/database security and audit configurations to verify that audit records are produced when other errors prevent attempts to modify categories of information.
If they are not produced, this is a finding.
Fix Text
Deploy a DBMS capable of producing the required audit records when it denies or fails to complete modification of categories of information.
Configure the DBMS to produce audit records when it denies modification of categories of information.
Configure the DBMS to produce audit records when other errors prevent modification of categories of information.
STIG Reference
- STIG
- Database Security Requirements Guide
- Version
- 4
- Release
- 5
- Rule ID
- SV-206623r961809_rule
All Occurrences
This vulnerability appears on 1 ship(s)
| Ship | Hull # | Source File | Status | Assigned To | Scan Date | Actions |
|---|---|---|---|---|---|---|
| USNS MONTFORD POINT | T-ESD-1 | Montford Point ShipCLIP DB V4R4.ckl | Unassigned | 2026-03-06T12:50:21.809591 | View in Context |