V-206595
CAT IIThe DBMS must generate time stamps, for audit records and application data, with a minimum granularity of one second.
- Ships Affected
- 1
- Total Findings
- 1
- Open
- 0
- Closed
- 1
Check Text
Review product documentation to verify that the DBMS can generate time stamps with a granularity of one second or finer. If it cannot, this is a finding.
Review audit log records produced by the DBMS for confirmation that time stamps are recorded to a precision of one second or finer. If not, this is a finding.
Review time stamp values in audit trail columns/fields in application data in the database. If the time stamps are not recorded to a precision of one second or finer, this is a finding.
Fix Text
Deploy a DBMS that can generate and record time stamps with a granularity of one second or finer.
Configure auditing so that the time stamps are recorded to a precision of one second or finer.
Modify applications and/or column/field definitions so that the time stamps in audit trail columns/fields in application data are recorded to a precision of one second or finer.
STIG Reference
- STIG
- Database Security Requirements Guide
- Version
- 4
- Release
- 5
- Rule ID
- SV-206595r961446_rule
All Occurrences
This vulnerability appears on 1 ship(s)
| Ship | Hull # | Source File | Status | Assigned To | Scan Date | Actions |
|---|---|---|---|---|---|---|
| USNS MONTFORD POINT | T-ESD-1 | Montford Point ShipCLIP DB V4R4.ckl | Unassigned | 2026-03-06T12:50:21.809591 | View in Context |