Documentation - V-245800

V-245800

Traditional Security Checklist

CAT I

Title

Information Security (INFOSEC) - Vault Storage/Construction Standards

Description

<VulnDiscussion>Failure to meet standards IAW the DOD Manual 5200.01, Volume 3, Appendix to Enclosure 3, for ensuring that there is required structural integrity of the physical perimeter surrounding a classified storage vault could result in the undetected loss or compromise of classified material. REFERENCES: CJCSI 6510.01F, INFORMATION ASSURANCE (IA) AND SUPPORT TO COMPUTER NETWORK DEFENSE (CND), Enclosure C, paragraphs 24.j. and 34. NIST Special Publication 800-53 (SP 800-53), Rev 4, Cont...

Fix Text (Documentation Requirement)

Vaults containing inspectable SIPRNet as well as other classified assets must have documented confirmation from supporting Facility Engineers to ensure each is built to the following standards: 1. As a Class A vault (concrete poured-in-place) built to Federal Standard (FED STD) 832 and specifically check/validate the following: a. Floor and Walls. Eight inches of reinforced concrete. Walls are to extend to the underside of the roof slab above. b. Roof/True Ceiling. Monolithic reinforced-concrete slab of thickness to be determined by structural requirements, but not less than the floors and walls. c. Class 5 Vault Door and Frame and be fitted with an FF-L-2740 combination lock. The vault door and frame unit must conform to Federal Specification AA-D-600 Class 5 vault door with lock m...

Documentation Status

Cancel